Pioneer Wincon P750 / 49


Trusted brand name of Pioneer Wincon.

Turbine design based on world famous Wincon WestWind ( Denmark) technology. Robust and rugged design to withstand the rigorous sub-tropical climatic conditions of the Indian Peninsula.

Easy to maintain even in the most remote installation locations.

Imported gear box from the world famous gear box manufacturer Moventas of Finland

This product of Pioneer P750/49 is approved by TUV-R.

The turbine is backed by full fledged Operation and Maintenance service provided by Pioneer Wincon.


NACELLE COMPONENTS

1. Blade

2. Shrink Disc

3. Bearing Housing

4. Main Shaft

5. Gear Box

6. CD Coupling

7. Generator

8. Anemometer & Windvane

9. Gear Box Cooler

10. Yaw Motor

11. Generator Console

12. Yaw Flange

13. Bottom Frame

14. Nose Cone

15. Hub

16. Top Panel

17. Material Lifting Crane

18. Rear Louver

19. Mechanical Break Unit

20. Yaw Pinion

Technical Spec

1.GENERAL DATA

Nominal Power::  750 KW
Rotor Diameter::  49.0m
Swept Area::  1886.5m2

2.OPERATIONAL DATA

Cut-in, Wind Speed::  3.0 m/s
Rated wind speed::  15.0 m/s
Cut-out, Wind speed::  25.0 m/s
Survival, wind speed for 2 sec max::  <52.5 m/s

3.ROTOR

No.of blades::  3
Rotor Position::  Upwind
Rotor Speed::  22.36 RPM
Rotor diameter::  49.0 m
Swept Area::  1886.5 m2
Tips Speed, Blade::  58.0 m/s
Weight, rotor(Including hub)::  14000 Kg

4.BLADE

Type::  HT 24
Profile Data::  NACA 63-4xx y FFA-W3
Length::  24.0 m
Material::  Fibre Glass Reinforeced Polyester(CRP)
Weight::  3400 kgs

5.GEARBOX

Type::  Helical - Cum - Planetary
Ratio::  1:67.68
Lubrication::  Forced Circulation
Oil Volume::  157 ltrs

6.GENERATOR

Type::   6-pole/4 -Pole induction
Rated power::  200KW /750 KW
Voltage::  690 V, 3 Phase, AC
Frequency::  50/60 Hz
Synchronous Speed::  1000 / 1500 RPM
Insulation Class::  H
Protection Class::  IP 55
Weight::  4500 kgs

7.WIND TURBINE CONTROLLER

Type::  Microprocessor
Power factor::  Cos phi > 0.95
Control and monitoring of ::  Imbalance
::  Generator Overlaod
::  Yaw drives overload
::  Automatic cable untwisting
::  Activation of brake systems
::  Voltage fluctuations, Grid
::  Grid Failure
::  Generator Over Speed
::  Rotor Over Speed
::  Automatic adjustment of power factor
Temp. measurments on::  Control panel, Gear Oil
::  High speed shaft bearings
::  Generator winding & Bearings
Optional::  Temp,main bearings
::  Transformer winding

8.TOWER

Type::  Lattice/Tubular
Height::  50/60/73 mtr
Surface Treatment::  Hot dip Galvanized

9.NACELLE

Weight, excl.rotor::  25000Kgs

10.SCADA

Type: 1)GPRS based remote monitoring, real time
2)SMS based monitoring of all turbine functions
Power Curve

power_curve_img


Brochure

You can download our brochure here.